Other / Structures (excluding prefabricated buildings of heading 9406) and parts of structures (for example, bridges and bridge-sections, lock-gates, towers, lattice masts, roofs, roofing frameworks, doors and windows and their frames and thresholds for doors, shutters, balustrades, pillars and columns), of iron or steel; plates, rods, angles, shapes, sections, tubes and the like, prepared for use in structures, of iron or steel.

STEEL POLYTUNNEL KIT FOR VEGETABLE GROWING.…

STEEL POLYTUNNEL KIT FOR VEGETABLE GROWING. SIZE 14FT X 100 FT. INCLUDES: 21 BOWS (1 AND 3/8" GALVANISED TUBING), 5/8" REBAR ANCHOR POSTS, STAINLESS STEEL ANCHOR BASE PLATES, TEK SCREWS, 24'X130' GREENHOUSE 5 MIL, 1000' ROPE, SIDE CURTAIN SUPPORT HOOKS

Classification justification: GIR 1, 3b & 6 NOTES TO HSEN 7308

BTI Reference:
IE17NT-14-4953.
Start date of validity:
.
End date of validity:
2020-03-07.

INDUSTRIAL RACKING STRUCTURE CONSISTING OF…

INDUSTRIAL RACKING STRUCTURE CONSISTING OF UPRIGHT AND CROSS BEAMS CONSTRUCTED INTO WAREHOUSE RACKING. GOODS ARE IMPORTED AS SET OF BEAMS AND ASSOCIATED FIXING TO BUILD ON SITE INTO RACKING. THE UPRIGHT AND HORIZONTAL BEAMS AND ASSOCIATED FIXINGS ARE MADE OF STEEL.

Classification justification: CLASSIFICATION HAS BEEN DETERMINED IN ACCORDANCE WITH THE FOLLOWING:- GENERAL INTERPRETATIVE RULES (GIR)S: GIR 1 HAS BEEN USED TO CLASSIFY THIS PRODUCT BY THE TERMS OF HEADING 7308 - STRUCTURES (EXCLUDING PREFABRICATED BUILDINGS OF HEADING 9406) AND PARTS OF STRUCTURES (FOR EXAMPLE, BRIDGES AND BRIDGE-SECTIONS, LOCK-GATES, TOWERS, LATTICE MASTS, ROOFS, ROOFING FRAMEWORKS, DOORS AND WINDOWS AND THEIR FRAMES AND THRESHOLDS FOR DOORS, SHUTTERS, BALUSTRADES, PILLARS AND COLUMNS), OF IRON OR STEEL; PLATES, RODS, ANGLES, SHAPES, SECTIONS, TUBES AND THE LIKE, PREPARED FOR USE IN STRUCTURES, OF IRON OR STEEL.

GIR 2A HAS BEEN USED AS THE GOODS ARE IMPORTED UNASSEMBLED. GENERAL INTERPRETATIVE RULE 3B HAS BEEN USED AS THE STEEL STRUCTURE IS CONSIDERED TO GIVE THE ITEM ITS ESSENTIAL CHARACTER.

GIR 6 HAS BEEN USED TO CLASSIFY THE GOODS TO SUBHEADING LEVEL 730820 - TOWERS AND LATTICE MASTS.

BTI Reference:
GB503590173.
Start date of validity:
.
End date of validity:
2020-08-03.

National keywords: WITH METAL FRAMES OF STEEL SHELVES CONNECTORS

LOWER STABS COMPONENTS, DESIGNED TO SUPPORT…

LOWER STABS COMPONENTS, DESIGNED TO SUPPORT A TIDAL TURBINE, WHICH WILL BE USED TO GENERATE ELECTRICITY. CONSTRUCTED FROM 550W LOW ALLOY STEEL. FUNNEL SHAPED, CAST FROM STEEL, MACHINED, OVERLAY WELDED AND PAINTED.

Classification justification: CLASSIFICATION HAS BEEN DETERMINED IN ACCORDANCE WITH THE FOLLOWING:- GENERAL INTERPRETATIVE RULES (GIR)S: GIR 1 HAS BEEN USED TO CLASSIFY THIS PRODUCT BY THE TERMS OF HEADING 7308 - STRUCTURES (EXCLUDING PREFABRICATED BUILDINGS OF HEADING 9406) AND PARTS OF STRUCTURES (FOR EXAMPLE, BRIDGES AND BRIDGE-SECTIONS, LOCK-GATES, TOWERS, LATTICE MASTS, ROOFS, ROOFING FRAMEWORKS, DOORS AND WINDOWS AND THEIR FRAMES AND THRESHOLDS FOR DOORS, SHUTTERS, BALUSTRADES, PILLARS AND COLUMNS), OF IRON OR STEEL; PLATES, RODS, ANGLES, SHAPES, SECTIONS, TUBES AND THE LIKE, PREPARED FOR USE IN STRUCTURES, OF IRON OR STEEL.

GIR 2A HAS BEEN USED AS THE GOODS ARE IMPORTED UNASSEMBLED. GENERAL INTERPRETATIVE RULE 3B HAS BEEN USED AS THE STEEL STRUCTURE IS CONSIDERED TO GIVE THE ITEM ITS ESSENTIAL CHARACTER.

GIR 6 HAS BEEN USED TO CLASSIFY THE GOODS TO SUBHEADING LEVEL 730820 - TOWERS AND LATTICE MASTS.

ALSO CLASSIFIED IN ACCORDANCE WITH: THE HSEN'S TO HEADING 7308 REFERS.

BTI Reference:
GB503522195.
Start date of validity:
.
End date of validity:
2020-06-07.

National keywords: OF STEEL STRUCTURES TOWERS

GAZEBO SIZE 10 FOOT BY 12 FOOT. HAS A RUSTPROOF…

GAZEBO SIZE 10 FOOT BY 12 FOOT. HAS A RUSTPROOF ALUMINIUM FRAME, WITH A GALVANISED STEEL ROOF AND CUPOLA.

Classification justification: CLASSIFICATION HAS BEEN DETERMINED IN ACCORDANCE WITH THE FOLLOWING:- GENERAL INTERPRETATIVE RULES (GIR)S GIR 1 HAS BEEN USED TO CLASSIFY THIS PRODUCT BY THE TERMS OF HEADING 7308 INCLUDES STRUCTURES (EXCLUDING PREFABRICATED BUILDINGS OF HEADING 9406) AND PARTS OF STRUCTURES (FOR EXAMPLE, BRIDGES AND BRIDGE-SECTIONS, LOCK-GATES, TOWERS, LATTICE MASTS, ROOFS, ROOFING FRAMEWORKS, DOORS AND WINDOWS AND THEIR FRAMES AND THRESHOLDS FOR DOORS, SHUTTERS, BALUSTRADES, PILLARS AND COLUMNS), OF IRON OR STEEL; PLATES, RODS, ANGLES, SHAPES, SECTIONS, TUBES AND THE LIKE, PREPARED FOR USE IN STRUCTURES, OF IRON OR STEEL GIR 6 HAS BEEN USED TO CLASSIFY THE GOODS TO SUBHEADING LEVEL 730890 OTHER THAN ELSEWHERE SPECIFIED IN THIS HEADING CN CODE 73089098 OTHER THAN SOLELY OR PRINCIPALLY OF SHEET ALSO CLASSIFIED IN ACCORDANCE WITH:- HSEN NOTES TO HEADING 7308 REFERS.

BTI Reference:
GB503290874.
Start date of validity:
.
End date of validity:
2019-11-02.

National keywords: WITH METAL FRAMES OF STEEL OF ALUMINIUM GARDEN CANOPIES STRUCTURES WITH ROOF

STEEL FRAMED BATHROOM PODS, TO BE PERMANENTLY…

STEEL FRAMED BATHROOM PODS, TO BE PERMANENTLY INSTALLED INTO BUILDINGS. THE BATHROOM PODS CONSISTS OF STEEL STRUCTURAL UNITS.

THE EXTERNAL DIMENSIONS ARE 2.3 METERS IN LENGTH, 2.2 METERS IN WIDTH, AND 2.5 METERS IN HEIGHT.

EACH BATHROOM POD INCLUDES WALLS, CEILINGS, AND FLOORS MADE OF STEEL FRAMES. THE BATHROOM PODS ARE NOT READY TO USE.

THEY ARE INTENDED TO BE INSTALLED INTO AN EXISTING BUILDING (E.G. A RESIDENTIAL HOUSE) WHERE POWER, WATER, AND WASTE PLUMBING ETC.

ARE SUPPLIED. ONCE INSTALLED INTO THE BUILDING, THE PODS CANNOT BE MOVED. THE BATHROOM PODS CANNOT BE USED INDEPENDENTLY AS A BUILDING UNIT.

IT IS ALSO TO BE DIFFERENTIATED FROM AUTOMATED BATHROOMS OR PORTABLE TOILETS.

Classification justification: CLASSIFICATION HAS BEEN DETERMINED IN ACCORDANCE WITH THE FOLLOWING:- GENERAL INTERPRETATIVE RULES (GIR)S GIR 1 HAS BEEN USED TO CLASSIFY THIS PRODUCT BY THE TERMS OF HEADING 7308 INCLUDES STRUCTURES (EXCLUDING PREFABRICATED BUILDINGS OF HEADING 9406) AND PARTS OF STRUCTURES (FOR EXAMPLE, BRIDGES AND BRIDGE-SECTIONS, LOCK-GATES, TOWERS, LATTICE MASTS, ROOFS, ROOFING FRAMEWORKS, DOORS AND WINDOWS AND THEIR FRAMES AND THRESHOLDS FOR DOORS, SHUTTERS, BALUSTRADES, PILLARS AND COLUMNS), OF IRON OR STEEL; PLATES, RODS, ANGLES, SHAPES, SECTIONS, TUBES AND THE LIKE, PREPARED FOR USE IN STRUCTURES, OF IRON OR STEEL GIR 6 HAS BEEN USED TO CLASSIFY THE GOODS TO SUBHEADING LEVEL 730890 OTHER THAN ELSEWHERE SPECIFIED IN THIS HEADING CN CODE 73089098 OTHER THAN SOLELY OR PRINCIPALLY OF SHEET ALSO CLASSIFIED IN ACCORDANCE WITH:- HSEN NOTES TO HEADING 7308 NOTE 3 SECTION XV

BTI Reference:
GB503080496.
Start date of validity:
.
End date of validity:
2019-06-30.

National keywords: OF METAL OF STEEL FOR BATHROOMS STRUCTURES

A VERTICALLY RISING DOOR USED INTERNALLY…

A VERTICALLY RISING DOOR USED INTERNALLY WITHIN A BUILDING, FIXED DIRECTLY TO THE STRUCTURE.

IT IS USED TO SUB-DIVIDE AREAS WITHIN A BUILDING AND OPERATES IN A CONCERTINA FORMATION AND FOLDS TO THE UNDERSIDE OF A STRUCTURE, NORMALLY WITHIN THE CEILING VOID AREA.

THE DOOR IS CONSTRUCTED OF STEEL AND ALUMINIUM.

Classification justification: CLASSIFICATION HAS BEEN DETERMINED IN ACCORDANCE WITH THE FOLLOWING:- GENERAL INTERPRETATIVE RULES (GIR)S GIR 1 HAS BEEN USED TO CLASSIFY THIS PRODUCT BY THE TERMS OF HEADING 7308 FOR STRUCTURES (EXCLUDING PREFABRICATED BUILDINGS OF HEADING 9406) AND PARTS OF STRUCTURES (FOR EXAMPLE, BRIDGES AND BRIDGE-SECTIONS, LOCK-GATES, TOWERS, LATTICE MASTS, ROOFS, ROOFING FRAMEWORKS, DOORS AND WINDOWS AND THEIR FRAMES AND THRESHOLDS FOR DOORS, SHUTTERS, BALUSTRADES, PILLARS AND COLUMNS), OF IRON OR STEEL; PLATES, RODS, ANGLES, SHAPES, SECTIONS, TUBES AND THE LIKE, PREPARED FOR USE IN STRUCTURES, OF IRON OR STEEL GIR 6 HAS BEEN USED TO CLASSIFY THE GOODS TO SUBHEADING LEVEL 730890 FOR OTHER THAN ELSEWHERE SPECIFIED IN THIS SUB-HEADING CN CODE 73089098 FOR OTHER THAN; SOLELY OR PRINCIPALLY OF SHEET ALSO CLASSIFIED IN ACCORDANCE WITH HARMONISED SYSTEM EXPLANATORY NOTES (HSEN) TO 7308

BTI Reference:
GB502761276.
Start date of validity:
.
End date of validity:
2021-11-26.

National keywords: OF STEEL OF ALUMINIUM FOR FOLDING STRUCTURES FOR WALLS

STEEL SNAP HOOK. EASY ATTACHMENT TO CABLE…

STEEL SNAP HOOK. EASY ATTACHMENT TO CABLE BASKET, PURLIN CLIPS AND LIGHT FITTINGS. AVAILABLE UPTO 90KG SAFE WORKING LOAD, WITH A 5:1 SAFETY FACTOR. COMES AS A READY TO USE KIT WITH WIRE AND GRIPPLE HANGER.

Classification justification: CLASSIFICATION HAS BEEN DETERMINED IN ACCORDANCE WITH THE FOLLOWING:- GENERAL INTERPRETATIVE RULES (GIR)S GIR 1 HAS BEEN USED TO CLASSIFY THIS PRODUCT BY THE TERMS OF HEADING 7326 - OTHER ARTICLES OF IRON OR STEEL GIR 6 HAS BEEN USED TO CLASSIFY THE GOODS TO SUBHEADING LEVEL 723690 - OTHER THAN ELSEWHERE SPECIFIED IN THIS HEADING CN CODE 73269098 - OTHER ARTICLES OF IRON OR STEEL OTHER THAN OPEN-DIE FORGED, CLOSED-DIE FORGED OR SINTERED TARIC CODE 7326909890 - OTHER THAN ELSEWHERE SPECIFIED IN THIS HEADING ALSO CLASSIFIED IN ACCORDANCE WITH HARMONIZED EXPLANATORY NOTES (HSEN) TO HEADING 7326

BTI Reference:
GB502623879.
Start date of validity:
.
End date of validity:
2021-08-24.

National keywords: OF STEEL HOOKS FOR BUILDINGS

COW CUBICLES FOR USE IN CATTLE HOUSE, USED…

COW CUBICLES FOR USE IN CATTLE HOUSE, USED TO SEPARATE ANIMALS BEDDING AREA. MADE OF STEEL AND PERMANENTLY ATTACHED OR HUNG FROM WALL OR POSTS IN CATTLE HOUSES.

Classification justification: GENERAL RULES 1 AND 6 FOR THE INTERPRETATION OF THE COMBINED NOMENCLATURE. THE TEXT TO TARIC CODES 7308, 7308 90, 7308 90 98 AND 7308 90 98 00. THE HARMONISED SYSTEM EXPLANATORY NOTES TO 7308.

BTI Reference:
IE15NT-14-2980.
Start date of validity:
.
End date of validity:
2021-05-11.

National keywords: OF STEEL TUBES FOR ANIMALS STRUCTURES

A RETENTION SOCKET DESIGNED TO SECURELY RETAIN…

A RETENTION SOCKET DESIGNED TO SECURELY RETAIN IN POSITION ALL TYPES OF ILLUMINATED OR NON-ILLUMINATED STREET FURNITURE AND POSTS.

CAN BE SUPPLIED WITH OR WITHOUT A DUCK FOOT BEND MANUFACTURED FROM CAST IRON. IS MANUFACTURED BY A PROCESS OF PRECISION CASTING, AND WITH A STEEL TUBE OR PVC DUCTING.

THE ESSENTIAL CHARACTER IS CONSIDERED TO BE A STEEL ITEM. MADE IN A RANGE OF SIZES. ALL POSTS ARE SECURED INTO THE SOCKET BY A PATENDED SPHEROIDAL CLAMPING SYSTEM.

IN USE A STAINLESS STEEL SET SCREW IS USED TO TIGHTEN THE CLAMP TO THE APPLICABLE PIECE OF FURNITURE.

THIS IS LOCATED IN A RECESSED CHAMBER, WHICH HAS A DRAIN HOLE TO PREVENT WATER BUILD UP. THE CHAMBER IN TURN SECURELY LOCKS TO PREVENT UNAUTHORISED ACCESS TO THE POST/STREET FURNITURE IN PLACE.

CAN BE SUPPLIED WITH OR WITHOUT A PROTECTIVE COATING, WHICH CAN BE SUPPLIED PRIOR TO ASSEMBLY, OR POST ASSEMBLY AS REQUIRED.

Classification justification: CLASSIFICATION HAS BEEN DETERMINED IN ACCORDANCE WITH THE FOLLOWING:- GENERAL INTERPRETATIVE RULES (GIR)S GIR 1 HAS BEEN USED TO CLASSIFY THIS PRODUCT BY THE TERMS OF HEADING 7308 INCLUDES STRUCTURES AND PARTS OF STRUCTURES.

GIR 3B HAS BEEN USED AS THE STEEL IS CONSIDERED TO BE THE ESSENTIAL CHARACTER. GIR 6 HAS BEEN USED TO CLASSIFY THE GOODS TO SUBHEADING LEVEL 730890 OTHER THAN ELSEWHERE SPECIFIED IN THIS HEADING CN CODE 73089098 OTHER THAN SOLELY OR PRINCIPALLY OF SHEET ALSO CLASSIFIED IN ACCORDANCE WITH THE HSENS TO HEADING 7308.

BTI Reference:
GB502399064.
Start date of validity:
.
End date of validity:
2021-04-21.

HARD TOP GAZEBO WITH A GALVANISED STEEL ROOF.…

HARD TOP GAZEBO WITH A GALVANISED STEEL ROOF. IT HAS AN ALUMINIUM RAIN GUTTER SYSTEM, AND ALUMINIUM AND STEEL SUBSTANTIAL PILLARS. IT IS CONSTRUCTED FROM 86% STEEL AND 14% ALUMINIUM THERE IS NO BASE TO THE GAZEBO

Classification justification: CLASSIFICATION HAS BEEN DETERMINED IN ACCORDANCE WITH THE FOLLOWING:- GENERAL INTERPRETATIVE RULES (GIR)S GIR 1 HAS BEEN USED TO CLASSIFY THIS PRODUCT BY THE TERMS OF HEADING 7308 INCLUDES STRUCTURES (EXCLUDING PREFABRICATED BUILDINGS OF HEADING 9406) AND PARTS OF STRUCTURES (FOR EXAMPLE, BRIDGES AND BRIDGE-SECTIONS, LOCK-GATES, TOWERS, LATTICE MASTS, ROOFS, ROOFING FRAMEWORKS, DOORS AND WINDOWS AND THEIR FRAMES AND THRESHOLDS FOR DOORS, SHUTTERS, BALUSTRADES, PILLARS AND COLUMNS), OF IRON OR STEEL; PLATES, RODS, ANGLES, SHAPES, SECTIONS, TUBES AND THE LIKE, PREPARED FOR USE IN STRUCTURES, OF IRON OR STEEL GIR 6 HAS BEEN USED TO CLASSIFY THE GOODS TO SUBHEADING LEVEL 730890 OTHER THAN ELSEWHERE SPECIFIED IN THIS HEADING CN CODE 73089098 OTHER THAN SOLELY OR PRINCIPALLY OF SHEET ALSO CLASSIFIED IN ACCORDANCE WITH:- HSEN NOTES TO HEADING 7308

BTI Reference:
GB502220419.
Start date of validity:
.
End date of validity:
2020-12-17.

National keywords: OF STEEL OF ALUMINIUM FOR THE GARDEN