CATHETERS.

KATÉTRY 11 CATETER 1 CATHÉTER 16 KATÉTER 1 CATETERI 10 KATETERIAI 3 KATHETERS 30 CEWNIKI 2 CATETER 11 CATETER 2 KATÉTERY 6 KATETRI 8

GUIDING CATHETER - THIS IS A GUIDING CATHETER…

GUIDING CATHETER - THIS IS A GUIDING CATHETER INTENDED TO PROVIDE A PATHWAY THROUGH WHICH A STENT IS INTRODUCED INTO A PATIENTS BODY. THIS DEVICE IS USED FOR CORONARY ANGIOPLASTY. IT IS INSERTED INTO THE LEG THEN UP THROUGH THE AORTA INTO THE CORONARY ARTERIES.

Nomenclature code:
Nomenclature code.
Start date of validity:
.

National keywords: MEDICAL EQUIPMENT MEDICAL INSTRUMENTS CATHETERS

PULL RING. IT FORMS PART OF A DISCONNECT…

sterile; catheters; medical equipment partssterile; catheters; medical equipment parts

PULL RING. IT FORMS PART OF A DISCONNECT CAP AND ITS PURPOSE IS TO MAINTAIN THE STERILITY OF THE DISCONNECT CAP FLUID PATH, POST STERILIZATION. THIS HELPS TO PROTECT A PATIENTS CATHETER BETWEEN DIALYSIS SOLUTION CHANGES. IT IS MADE FROM PL-1914.

Nomenclature code:
Nomenclature code.
Start date of validity:
.

National keywords: STERILE CATHETERS MEDICAL EQUIPMENT PARTS

BALLOON CATHETHER WHICH IS INFLATED BY THE…

medical equipment; catheters; surgical equipment

BALLOON CATHETHER WHICH IS INFLATED BY THE PHYSICIAN AND IS USED TO OPEN A BLOCKAGE IN AN ARTERY. THERE ARE MARKER BANDS UNDER THE BALLOON WHICH HELPS THE PHYSICIAN POSITION THE BALLOON WHERE IT IS NEEDED.THIS IS A MEDICAL DEVICE.

Nomenclature code:
Nomenclature code.
Start date of validity:
.

National keywords: MEDICAL EQUIPMENT CATHETERS SURGICAL EQUIPMENT

PARTS OF A VASCULAR SURGICAL DEVICE, THE…

carbon; nylon; surgical instruments; catheters

PARTS OF A VASCULAR SURGICAL DEVICE, THE DEVICES ARE DESIGNED TO DELIVER POLYESTER SUTURE(S) TO CLOSE FEMORAL ARTERY PUNCTURE SITES FOLLOWING CATHERISATION PROCEDURE.

BOTH PARTS FORM PART OF THE GUIDE ASSEMBLY AND ARE BONDED TOGETHER. THE SUTURE RUNS THROUGH THE BONDED PART.

THE DEVICES FORM PART OF THE DEPLOYMENT SYSTEM THAT WILL ALLOW A PHYSICIAN TO SUTURE A TEAR IN THE BODY.

THE MATERIAL COMPOSTIION OF BOTH PARTS ARE NYLON 6/6 WITH 40% CARBON FIBRE.

Nomenclature code:
Nomenclature code.
Start date of validity:
.

National keywords: CARBON NYLON SURGICAL INSTRUMENTS CATHETERS

PROTECTIVE PLUG. IT IS AN ACCESSORY PROVIDING…

PROTECTIVE PLUG. IT IS AN ACCESSORY PROVIDING ADDITIONAL PROTECTION LAYER FOR FEMALE LUER CONNECTOR OR THE CONNECTOR OF THE SYRINGE UNIT. ONCE ATTACHED IT SERVES AS A CAP AND MAINTAINS STERILITY ON THE CONNECTOR'S SEPTUM. THE PRODUCT IS MADE FROM ABS (ACRYLONITRILE BUTADIENE STYRENE).

Nomenclature code:
Nomenclature code.
Start date of validity:
.

National keywords: OF PLASTIC STYRENE CATHETERS CONNECTIONS ACRYLONITRILE BUTADIENE

MANDREL- PARYLENE COATED STAINLESS STEL WIRE-…

MANDREL- PARYLENE COATED STAINLESS STEL WIRE- USED AS A PRODUCTION TOOL IN THE MANUFACTURE OF CATHETERS, THE WIRE IS INSERTED INTO THE CATHETER TO ENSURE THAT WHEN WORK IS BEEN COMPLETED ON THE CATHETER DURING THE MANUFACTURE PROCESS IT DOES NOT COLLAPSE AND IS REMOVED AGAIN AFTER USE.

THE MANDREL IS NOT A MEDICAL PRODUCT, IT IS A PROCESSING AID AND IS NOT PART OF THE FINISHED PRODUCT

Nomenclature code:
Nomenclature code.
Start date of validity:
.

National keywords: BASE METALS STEELS WIRES CATHETERS STAINLESS STEELS

A CORONARY STENT & DELIVERY APPARATUS…

A CORONARY STENT & DELIVERY APPARATUS FOR PERMANENT IMPLANTATION OF THE STENT IN THE BODY.

IT CONSISTS OF A THIN ROUNDED METAL STENT MADE OF COBALT ALLOY. THE STENT IS AVAILABLE IN VARIOUS DIAMETERS FROM 2.25MM TO 4MM AND IN VARIOUS LENGTHS FROM 8MM TO 30MM.

THE COMPONENT PARTS CONSIST OF STAINLESS STEEL GUIDEWIRE WITH LOOP END COATED WITH PLASTIC PROTECTIVE SHEATH, THE SHEATH CONTAINS TWO MARKER BANDS.

IT CONTAINS A 29 GAGE CANNULA AND MICRO TRAC CATHETER. IT IS CONTAINED IN AN OUTER TUBING OF PLASTIC TOGETHER WITH A LOOPER ACCESSORY AND ACCESSORY CLIP.

Nomenclature code:
Nomenclature code.
Start date of validity:
.

National keywords: OF PLASTIC MEDICAL EQUIPMENT OF STEEL WIRE MEDICAL INSTRUMENTS IMPLANTS CATHETERS CANNULAS

THERMOGRIP GLASS MOULD A MOULD MADE OF GLASS,…

THERMOGRIP GLASS MOULD A MOULD MADE OF GLASS, HAVING A LINEAR COEFFICIENT OF EXPANSION NOT EXCEEDING 5 X 10-6 PER KELVIN WITHIN A TEMPERATURE RANGE OF 0 DEGREES CELSIUS TO 300 DEGREES CELSIUS. THE GLASS MOULD IS SUBSEQUENTLY USED IN THE MANUFACTURING PROCESS OF A CATHETER.

Nomenclature code:
Nomenclature code.
Start date of validity:
.

National keywords: OF GLASS MOULDS CATHETERS GLASS

SIDEARM: COMPONENT WHICH IS ATTACHED TO A…

SIDEARM: COMPONENT WHICH IS ATTACHED TO A CATHETER AND USED TO CONNECT AIR SUPPLY TO INFLATE BALLOON DURING A SURGICAL PROCEDURE. ALSO USED WHERE GUIDE WIRE CAN BE INSERTED AND USED FOR IDENTIFICATION. THE MATERIAL COMPOSITION IS HARD PLASTIC.

Nomenclature code:
Nomenclature code.
Start date of validity:
.

National keywords: OF PLASTIC MEDICAL EQUIPMENT CATHETERS MEDICAL EQUIPMENT PARTS

CATHETER SUB-ASSEMBLY. THE PRODUCTS CONSIST…

CATHETER SUB-ASSEMBLY. THE PRODUCTS CONSIST OF 20CM OR 40CM PLASTIC TUBES RANGING IN DIAMETER FROM 2.66MM UP TO 5.33MM WITH A CONNECTOR AT ONE END AND ARE USED IN THE MANUFACTURE OF CATHETERS.

THE FINISHED CATHETER IS DEFINED AS A HOLLOW TUBE THAT IS INSERTED INTO THE BLADDER THROUGH THE URETHRA TO REMOVE URINE FROM THE BLADDER.

THEY ARE FOR USE IN SELF CATHETERISATION AND ARE FOR SINGLE USE ONLY.

Nomenclature code:
Nomenclature code.
Start date of validity:
.

National keywords: OF PLASTIC CATHETERS MEDICAL TUBING WITH CONNECTORS